Search results for "pole [approximation]"

showing 10 items of 522 documents

Multi-mycotoxin analysis in wheat semolina using an acetonitrile-based extraction procedure and gas chromatography–tandem mass spectrometry

2012

A new analytical method for the rapid and simultaneous determination of ten mycotoxins including patulin, zearalenone and eight trichothecenes (nivalenol, fusarenon-X, diacetoxyscirpenol, 3-acetyl-deoxynivalenol, neosolaniol, deoxynivalenol, T-2 and HT-2) in wheat semolina has been developed and optimized. Sample extraction and purification were performed with a modified QuEChERS-based (acronym of Quick, Easy, Cheap, Effective, Rugged and Safe) procedure and determined by gas chromatography (GC) coupled to triple quadrupole instrument (QqQ). This is the first paper on the application of GC-QqQ-MS/MS to analysis of mycotoxins. Careful optimization of the gas chromatography-tandem mass spectr…

AcetonitrilesChromatographyGas Chromatography/Tandem Mass SpectrometryCalibration curveFlourLiquid-Liquid ExtractionOrganic ChemistryAnalytical chemistryReproducibility of ResultsGeneral MedicineHydrogen-Ion ConcentrationMycotoxinsQuechersSensitivity and SpecificityBiochemistryGas Chromatography-Mass SpectrometryDiacetoxyscirpenolAnalytical ChemistryTriple quadrupole mass spectrometerPatulinchemistry.chemical_compoundchemistryTandem Mass SpectrometryGas chromatographyGas chromatography–mass spectrometryJournal of Chromatography A
researchProduct

Search for neutral MSSM Higgs bosons at LEP

2006

The four LEP collaborations, ALEPH, DELPHI, L3 and OPAL, have searched for the neutral Higgs bosons which are predicted by the Minimal Supersymmetric Standard Model (MSSM). The data of the four collaborations are statistically combined and examined for their consistency with the background hypothesis and with a possible Higgs boson signal. The combined LEP data show no significant excess of events which would indicate the production of Higgs bosons. The search results are used to set upper bounds on the cross-sections of various Higgs-like event topologies. The results are interpreted within the MSSM in a number of "benchmark" models, including CP-conserving and CP-violating scenarios. Thes…

AlephPARTICLE PHYSICS; LARGE ELECTRON POSITRON COLLIDER; ALEPH; DELPHI; L3; OPALPhysics and Astronomy (miscellaneous)Parameter space01 natural sciencesOPAL DETECTORHigh Energy Physics - ExperimentHigh Energy Physics - Experiment (hep-ex)[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex]Event (probability theory)BosonPhysicsEXPLICIT CP VIOLATIONROOT-S=189 GEVOPALFLAVOR INDEPENDENT SEARCHParticle physics - ExperimentPhysicsSettore FIS/01 - Fisica SperimentaleHiggs particle. search forSUPERGAUGE TRANSFORMATIONSALEPHLARGE ELECTRON POSITRON COLLIDERALEPH DELPHI L3 OPALSUPERSYMMETRIC STANDARD MODELROOT-SL3Higgs bosonPARTICLE PHYSICSParticle physicselectron positron. colliding beamselectron positron. annihilationFOS: Physical sciencessupersymmetric standard model;; explicit cp violation;; electric-dipole moment;; e(+)e(-) collisions;; root-s=189 gev;; opal detector;; root-s;; z(0) decays;; supergauge transformations;; radiative-correctionsHiggs particle. electroproductionddc:500.2-SUPERSYMMETRIC STANDARD MODEL; EXPLICIT CP VIOLATION; FLAVOR INDEPENDENT SEARCH; ELECTRIC-DIPOLE MOMENT; E(+)E(-) COLLISIONS; ROOT-S; ROOT-S=189 GEV; OPAL DETECTOR; Z(0) DECAYS; SUPERGAUGE TRANSFORMATIONSHiggs particleLEP colliderNext-to-Minimal Supersymmetric Standard ModelELECTRIC-DIPOLE MOMENTE(+)E(-) COLLISIONSConsistency (statistics)0103 physical sciencesddc:530High Energy Physics010306 general physicsEngineering (miscellaneous)DELPHIelectron positron010308 nuclear & particles physicsHigh Energy Physics::PhenomenologyHiggs BosonLEPHIGGSHiggs boson standard modelZ(0) DECAYSExperimental High Energy PhysicsHigh Energy Physics::ExperimentHiggs Boson; LEP colliderMSSMMinimal Supersymmetric Standard ModelHiggs
researchProduct

First experimental proof of asymmetric charge transfer in ICP-MS/MS (ICP-QQQ-MS) through isotopically enriched oxygen as cell gas

2014

The quantification of a variety of elements in the field of ICP-MS is restricted by isobaric interferences. The recent development of ICP-MS/MS (“triple quadrupole” configuration) offers a new way to solve the problem of the detection of such elements affected by interferences because the signal caused by either the analyte or the isobaric interference can be shifted to another m/z through reactions with the cell gas (oxygen, ammonia or hydrogen). This system consists of two quadrupoles (Q1 and Q2) with a collision/reaction cell in between. When using the MS/MS mode of this configuration it becomes possible to restrict the ions entering the cell to a defined m/z and therefore get a better i…

AnalyteHydrogenAnalytical chemistrychemistry.chemical_elementOxygenAnalytical ChemistryTriple quadrupole mass spectrometerIonAmmoniachemistry.chemical_compoundchemistryIsobaric processInductively coupled plasma mass spectrometrySpectroscopyJournal of Analytical Atomic Spectrometry
researchProduct

Application of ultra-high pressure liquid chromatography linear ion-trap orbitrap to qualitative and quantitative assessment of pesticide residues

2014

Abstract The analysis of pesticides residues using a last generation high resolution and high mass accuracy hybrid linear ion trap-Orbitrap mass spectrometer (LTQ-Orbitrap-MS) was explored. Pesticides were extracted from fruits, fish, bees and sediments by QuEChERS and from water by solid-phase with Oasis HLB cartridges. Ultra-high pressure liquid chromatography (UHPLC)–LTQ-Orbitrap mass spectrometer acquired full scan MS data for quantification, and data dependent (dd) MS 2 and MS 3 product ion spectra for identification and/or confirmation. The regression coefficients ( r 2 ) for the calibration curves (two order of magnitude up to the lowest calibration level) in the study were ≥0.99. Th…

AnalyteMeatCalibration curveAnalytical chemistryOrbitrapQuechersMass spectrometryBiochemistryMass SpectrometryAnalytical Chemistrylaw.inventionlawAnimalsQuadrupole ion trapChromatography High Pressure LiquidChromatographyPesticide residueChemistryOrganic ChemistryFishesPesticide ResiduesGeneral MedicineBeesPesticideFruitEnvironmental PollutantsWater Pollutants ChemicalJournal of Chromatography A
researchProduct

Applicability of hybrid linear ion trap-high resolution mass spectrometry and quadrupole-linear ion trap-mass spectrometry for mycotoxin analysis in …

2012

Abstract Recent developments in mass spectrometers have created a paradoxical situation; different mass spectrometers are available, each of them with their specific strengths and drawbacks. Hybrid instruments try to unify several advantages in one instrument. In this study two of wide-used hybrid instruments were compared: hybrid quadrupole-linear ion trap-mass spectrometry (QTRAP ® ) and the hybrid linear ion trap-high resolution mass spectrometry (LTQ-Orbitrap ® ). Both instruments were applied to detect the presence of 18 selected mycotoxins in baby food. Analytical parameters were validated according to 2002/657/CE. Limits of quantification (LOQs) obtained by QTRAP ® instrument ranged …

Analytical chemistryMass spectrometryOrbitrapBiochemistryMass SpectrometryAnalytical ChemistryIonlaw.inventionBaby foodchemistry.chemical_compoundlawLimit of DetectionMSPDHumansQuadrupole ion trapMycotoxinQTRAPChromatography High Pressure LiquidChromatographyBaby foodOrganic ChemistryInfantGeneral MedicineMycotoxinsOrbitrapchemistryQuadrupoleInfant FoodJournal of chromatography. A
researchProduct

Ultra high performance liquid chromatography-time-of-flight high resolution mass spectrometry in the analysis of hexabromocyclododecane diastereomers…

2014

An efficient ultra high performance liquid chromatography (UHPLC)-time-of-flight high resolution mass spectrometry (TOF-HRMS) method was elaborated for the determination of hexabromocyclododecane (HBCD) diastereomers in fish samples and compared against UHPLC-Orbitrap-HRMS and UHPLC-triple quadrupole (QqQ) tandem MS (MS/MS) techniques. The TOF-HRMS analyzer was operated at high resolution (>10000 full width at half maximum (FWHM)) with scanning the m/z range from 600 to 700, to achieve picogram quantitation limits. The effects of various operational parameters on the instrumental response were systematically investigated. Evaluation of the influence of sample clean-up procedure steps on sig…

Analytical chemistryTandem mass spectrometryOrbitrapBiochemistryMass SpectrometryAnalytical Chemistrylaw.inventionMatrix (chemical analysis)Gel permeation chromatographychemistry.chemical_compoundColumn chromatographylawTandem Mass SpectrometryAnimalsMuscle SkeletalChromatography High Pressure LiquidHexabromocyclododecaneChromatographyEelsOrganic ChemistryFishesReproducibility of ResultsGeneral MedicineRepeatabilityTriple quadrupole mass spectrometerHydrocarbons BrominatedchemistryWater Pollutants ChemicalEnvironmental MonitoringJournal of chromatography. A
researchProduct

Ultracold Rare-Earth Magnetic Atoms with an Electric Dipole Moment

2018

We propose a new method to produce an electric and magnetic dipolar gas of ultracold dysprosium atoms. The pair of nearly degenerate energy levels of opposite parity, at 17513.33 cm$^{-1}$ with electronic angular momentum $J=10$, and at 17514.50 cm$^{-1}$ with $J=9$, can be mixed with an external electric field, thus inducing an electric dipole moment in the laboratory frame. For field amplitudes relevant to current-day experiments, we predict a magnetic dipole moment up to 13 Bohr magnetons, and an electric dipole moment up to 0.22 Debye, which is similar to the values obtained for alkali-metal diatomics. When a magnetic field is present, we show that the electric dipole moment is strongly…

Angular momentumAtomic Physics (physics.atom-ph)General Physics and AstronomyFOS: Physical sciences[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]01 natural sciencesAtomicPhysics - Atomic Physics010305 fluids & plasmas[PHYS.QPHY]Physics [physics]/Quantum Physics [quant-ph]Electric field0103 physical sciencesPhysics::Atomic Physics010306 general physicsPhysicsQuantum PhysicsMagnetic moment[PHYS.PHYS.PHYS-ATOM-PH]Physics [physics]/Physics [physics]/Atomic Physics [physics.atom-ph]Degenerate energy levelsMolecularand Optical Physics3. Good healthMagnetic fieldElectric dipole momentDipoleAmplitudeQuantum Gases (cond-mat.quant-gas)[PHYS.PHYS.PHYS-CHEM-PH]Physics [physics]/Physics [physics]/Chemical Physics [physics.chem-ph]Atomic physicsCondensed Matter - Quantum GasesQuantum Physics (quant-ph)
researchProduct

Chronique d’une découverte exceptionnelle : La nécropole et la tombe « princière » de Lavau

2017

Cet article présente la fouille archéologique préventive de Lavau sous l'angle de l'aventure humaine, du décapage, jusqu'au prélèvement du mobilier de la tombe et la fin de l'opération. Il est complété par des éléments de contenu à propos de l'environnement du site, de l'architecture funéraire des grands monuments régionaux contemporains de celui de Lavau, de la datation de la tombe princière et des caractéristiques qui font de cette découverte un ensemble exceptionnel.

Archéologie préventive[SHS.ARCHEO] Humanities and Social Sciences/Archaeology and Prehistorymonument funéraire[SHS.ARCHEO]Humanities and Social Sciences/Archaeology and Prehistory[ SHS.ARCHEO ] Humanities and Social Sciences/Archaeology and PrehistoryLavauTombe princièrenécropole protohistorique
researchProduct

New horizons for fundamental physics with LISA

2022

K. G. Arun et al.

AstrofísicaPROTOPLANET MIGRATIONFísica-Modelos matemáticosPhysics and Astronomy (miscellaneous)gr-qcFOS: Physical sciencesGeneral Relativity and Quantum Cosmology (gr-qc)GRAVITATIONAL-WAVEShorizonFundamental physicGeneral Relativity and Quantum CosmologyPhysics Particles & FieldsGravitational wavesLIGO (Observatory)Tests of general relativitySettore FIS/05 - Astronomia e AstrofisicaDARK-MATTERFísica matemáticaKOZAI MECHANISMHigh Energy PhysicsGENERAL-RELATIVITYFundamental physics; Gravitational waves; LISA; Tests of general relativityFundamental physicsPRIMORDIAL BLACK-HOLESLISAScience & TechnologyGeneral Relativity and Cosmology83CXXPhysicsgravitation: interactiongravitational radiationFísicaCompactQUANTUM-GRAVITYPhysical SciencesAstronomia[PHYS.GRQC]Physics [physics]/General Relativity and Quantum Cosmology [gr-qc]fundamental physics; gravitational waves; LISA; test of general relativityMODIFIED GRAVITYtest of general relativityGravitational waveMULTIPOLE MOMENTSHUBBLE CONSTANT
researchProduct

Discovery potential of xenon-based neutrinoless double beta decay experiments in light of small angular scale CMB observations

2013

The South Pole Telescope (SPT) has probed an expanded angular range of the CMB temperature power spectrum. Their recent analysis of the latest cosmological data prefers nonzero neutrino masses, with Sigma m(nu) = (0.32 +/- 0.11) eV. This result, if con firmed by the upcoming Planck data, has deep implications on the discovery of the nature of neutrinos. In particular, the values of the effective neutrino mass m(beta beta) involved in neutrinoless double beta decay (beta beta 0 nu) are severely constrained for both the direct and inverse hierarchy, making a discovery much more likely. In this paper, we focus in xenon-based beta beta 0 nu experiments, on the double grounds of their good perfo…

AstrofísicaPhysics - Instrumentation and DetectorsPhysics::Instrumentation and DetectorsCosmic microwave backgroundchemistry.chemical_elementdouble beta decayFOS: Physical sciences7. Clean energy01 natural sciencesPartícules (Física nuclear)High Energy Physics - ExperimentNuclear physicssymbols.namesakeHigh Energy Physics - Experiment (hep-ex)XenonHigh Energy Physics - Phenomenology (hep-ph)Double beta decay0103 physical sciencesPlanck010306 general physicsPhysicsCosmologiaTime projection chamber010308 nuclear & particles physicsAstrophysics::Instrumentation and Methods for AstrophysicsAstronomy and Astrophysicsneutrino masses from cosmologyInstrumentation and Detectors (physics.ins-det)3. Good healthHigh Energy Physics - PhenomenologyMAJORANASouth Pole Telescopechemistry13. Climate actionsymbolsNeutrino
researchProduct